External CO2 Monitor Capnoxi Sidestream Plug-In Etco2 Sensor

CAPNOVETCapnoVet sidestream EtCO2(End Tidal CO2) sensor. It does not occupy any host space and connects to host just with one eight-pin plug.CapnoVet features cutting-edge technology for measurement of instantaneous CO2 concentration, respiration rate, end-tidal CO2 concentration, inspired CO2 concentration, inspiration tim

Featured Products

CAPNOVET

CapnoVet sidestream EtCO2(End Tidal CO2) sensor. It does not occupy any host space and connects to host just with one eight-pin plug.
CapnoVet features cutting-edge technology for measurement of instantaneous CO2 concentration, respiration rate, end-tidal CO2 concentration, inspired CO2 concentration, inspiration time and expiration time.
It is generally used with patient monitor and anesthetic machine.
With a sampling rate low to 50 mL/min, it is ideal for use on adult, pediatric and infant patients; Patients undergoing procedural sedation; And short- term monitoring of intubated patients.

External CO2 Monitor Capnoxi  Sidestream   Plug-in Etco2 Sensor 
FEATURES
External CO2 monitor Capnoxi
 
Sidestream  plug-in etco2 sensor 

 
State-of-the-art Non-dispersive infrared (NDIR) technology, dual wavelength, no moving parts Breath-by-breath CO2 monitoring 
Isolated design of gas & electronic 
Sample rate low to 50 mL/min, microstream 
Barometer pressure and temperature compensation 
Range calibration in 0 15% by manufacturer 
Fast warmup time ensures full accuracy within 5 minutes 
Oxygen, N2O and anesthetic compensation for accurate measurement Low power consumption less than 1.5W 
Long life time pump from Germany company 
Fully compatible with Respronics Loflo sensor module
 
Oximeter (options) :
1-Meditech Pulse Oximeter
2-Nellcor Pulse Oximeter 
Adult, pediatric or neonate. 
 
The Analog Output Module is convenient to connect with to all kinds of multi-lead sleep monitors
Easy to connect and fix with anesthetic machine  
 
External CO2 Monitor Capnoxi  Sidestream   Plug-in Etco2 Sensor 
Capnoxi Display
Display:
1.  Alarm Information
2.  SD Card Status Symbol:
   If this symbol is shown, which indicates the system has detected the SD card successfully. Otherwise, the system has not detected the SD card.
3.  CO2 Pump Status Symbol:
   This symbol indicates that the CO2 pump is on. If the system doesn't show this symbol, which says the CO2 pump is off or faulty.
4.  Alarm Speaker Status Symbol:
   Alarm speaker is suspended. 
   Alarm speaker is off. 
   Alarm system is suspended. 
5.  Battery Status Symbol
6.  System Time
7.  Real-time Physiological Parameters
8.  Parameter in Alarm Status
9.  CO2 waveform 50 and 78 reference lines.
10. Real-time Waveforms


 
SPECIFICATIONS
Transducer Type Sidestream EtCO2 sensor 
Sample Rate 50 mL/min, ± 10mL/min. Microstream
Principle of Operation Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts 
Initialization Time Capnogram displayed in less than 5 seconds Reaching full specifications within 5 minutes.  
CO2 Measure Range 0 --114 mmHg
0-15%
0 --15.2kPa 
CO2 Resolution 0.1 mmHg     0 to 50 mmHg
0.25 mmHg         50 to 114 mmHg
CO2 Accuracy 0-40 mmHg ± 2mmHg
40-114 mmHg       ± 5% of reading
Respiratory Rate Range2 to 120 Breaths Per Minute (BPM)
Accuracy ± 1 breath
Calibration No routine user calibration required 
Compensation Automatic Barometer Pressure 400 - 800 mmHg. User selectable O2 / N2O compensation.  
Voltage Requirements 5.0 VDC ± 5% 
Power Consumption Less than 1.5 Watts typical.  
Temperature and Humidity Operating: 0 to 50 degree Celsius, 10 to 90% RH, non-condensing 
Storage: -40 to 70 degree Celsius, < 90% RH, non-condensing
Data Interface RS232, bi-directional, 19200 baud rate, standard N-8-1.
Fully compatible with Respironics LoFlo communication protocol 
CPT protocol available
Phasein protocol available
Artema protocol available
User-define protocol available
Data Output 

CO2 gas concentration (mm Hg), End-tidal CO2, Inspired CO2, Respiratory Rate, Automatic barometric pressure compensation. 

 
External CO2 Monitor Capnoxi  Sidestream   Plug-in Etco2 Sensor 
 
 
STANDARD ACCESSORIES:

CO2 Sample Line.   ......... 1Pcs
Nasal Tube     .................. 1Pcs
Power Adapter    .............. 1Pcs
Water-trap Column  ......... 1Pcs
Airway Adapter    ............. 1Pcs

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours