A novel 3D-printed lab-on-a-chip device concurrently detects SARS-CoV-2 nucleic acid and anti-SARS-CoV-2 antibodies in saliva

2022-08-13 05:00:37 By : Mr. Johnny chan

We use cookies to enhance your experience. By continuing to browse this site you agree to our use of cookies. More info.

In a recent study published in Nature Biomedical Engineering, researchers described the development and applications of a three-dimensional (3D)-printed lab-on-a-chip (LOC) device that quickly detected the presence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in patient's saliva.

The coronavirus disease 2019 (COVID-19) pandemic highlighted the need for multi-functional and cost-effective diagnostics methods that could seamlessly diagnose acute and convalescent SARS-CoV-2 infections and a patients’ immunization status following vaccination. Despite the advances in SARS-CoV-2 diagnosis, such a LOC platform for point-of-care (POC) use is yet unavailable.

The clustered regularly interspaced short palindromic repeats (CRISPR)-based diagnostics have garnered the attention of the scientific community recently. They capitalize on endonucleases, such as CRISPR-associated protein 12a (Cas12a), and yield highly specific results under physiological conditions. When coupled with amplification techniques, such as loop-mediated isothermal amplification (LAMP), these CRISPR-based assays become truly worthwhile. Then, they can perform SARS-CoV-2 ribonucleic acid (RNA) detection in clinical samples, typically in the attomolar (10−18) range.

Previously published POC CRISPR-based electrochemical detection platforms have not been sensitive enough to detect clinically relevant quantities of SARS-CoV-2 RNA. Although the graphene field effect transistor-based EC biosensors had similar sensitivity to SARS-CoV-2 RNA, those assays lacked multiplexing capabilities and were validated using viral transport media-based nasopharyngeal swab samples.

In the present study, researchers described a LOC multiplexed diagnostic device capable of simultaneously detecting SARS-CoV-2 RNA and anti-SARS-CoV-2 antibodies from unprocessed saliva samples. They ensured that saliva samples were exposed to a proteinase K solution and then heated to 55°C for 15 minutes. Another round of heating at 95 °C for five minutes in high-power resistors allowed SARS-CoV-2 RNA lysis and nuclease inactivation. The saliva samples were pumped over the polyethersulfone (PES) membrane within the reaction chamber to ensure the proper binding of viral RNA. Conversely, saliva for antibody detection was pumped over the EC sensor chip directly, which the researchers read using a potentiostat. This device had an integrated microfluidic chip to enable automated liquid handling for saliva sample preparation while ensuring proper RNA amplification for CRISPR-based RNA detection. Additionally, it had a sensitive readout for SARS-CoV-2 RNA and host antibodies on the same electrochemical (EC) biosensor chip.

The researchers designed a biotinylated single-stranded deoxyribonucleic acid (ssDNA) replication protein A (RP), which partially hybridized to peptide nucleic acid (PNA) capture probes and integrated the CRISPR-based molecular assay onto the EC sensor platform. Further, they varied the concentration and incubation time of the RP to obtain a rapid, high signal-to-noise ratio. Next, they incubated functionalized EC biosensors with saliva samples containing a mixture of the LAMP/Cas12a, which collaterally cleaved the biotinylated ssDNA RP. This led to a reduction in the binding of polystreptavidin-horseradish peroxidase (HRP); thus, a reduction in the precipitation of tetramethylbenzidine (TMB) deposited locally on the electrode surface. In other words, the LAMP amplification increased the signal sensitivity over and above the sensor’s limit of detection (LOD).

The use of polystreptavidin-HRP/TMB-based reaction chemistry for readout enabled further amplification of the EC signal for both the serological and CRISPR-based RNA sensors. The team measured peak current or reduced precipitation of TMB using cyclic voltammetry (CV); varying the voltage between −0.5 and 0.5 volts. Lastly, the researchers validated the CRISPR-EC sensor platform used in the study to determine its clinical value.

The study describes a novel device that used polystreptavidin-HRP/TMB-based reaction chemistry for readout to amplify the EC signal for both the serological and CRISPR-based RNA sensors. Further, this device used a customized molecular assay which, through optimization of RNA-dependent Cas12a cleavage of a biotinylated ssDNA RP, detected target nucleic acid with more sensitivity than fluorescence-based CRISPR-Cas12a assays but in a similar timeframe.

Of all the RP concentrations tested, one nanomolar (nM) RP and five minutes of incubation produced the highest signal with no background noise. The CRISPR-EC sensor platform yielded a LOD of 0.8 copies per µl, displaying a sensitivity of nearly four times compared to the fluorescence-based assays used for validating the primers. The current from the EC electrodes clearly distinguished the SARS-CoV-2-negative and positive saliva samples. Additionally, receiver operating characteristic (ROC) curve analysis demonstrated a correlation between reverse transcriptase-quantitative polymerase chain reaction (RT–qPCR) and CRISPR-Cas12a-based detection assay. Furthermore, its EC sensor detected IgG at an accuracy of 100% in clinical samples unlike the enzyme-linked immunosorbent assay (ELISA).

Additionally, the researchers noted that the simultaneous multiplexed detection of different viral antigens, including spike (S)1-receptor-binding domain (RBD), S1, and nucleocapsid (N), led to increased diagnostic sensitivity. Furthermore, this device used saliva, a better alternative to nasopharyngeal swabs for SARS-CoV-2 diagnosis. Saliva is easier to collect than nasopharyngeal swabs. Additionally, it provides nucleic acid and serological data during and after infection or vaccination.

The compact and sealed design of this diagnostic device, reduced user steps to avoid contamination or human error, makes it an attractive POC testing system even for untrained end-users. Most importantly, this microfluidic LOC platform clearly distinguished four types of SARS-CoV-2 clinical saliva samples within two hours, which further highlights its utility as a POC testing system.

To summarize, this user-friendly, inexpensive, 3D-printed LOC device, with streamlined workflow and multiplexing capabilities, could empower clinicians and the public alike, simultaneously making it easier to quickly and easily monitor the infection and immune status of COVID-19 patients. This device could provide insights into SARS-CoV-2 infection stages to help curb COVID-19 spread; likewise, it could provide data on anti-SARS-CoV-2 antibody titers to help understand how novel SARS-CoV-2 variants might affect individuals with immunity acquired through infection, vaccination, or a combination of both.

Posted in: Medical Science News | Medical Research News | Disease/Infection News

Tags: Antibodies, Antibody, Assay, Biosensor, CHIP, Contamination, Coronavirus, Coronavirus Disease COVID-19, covid-19, CRISPR, Diagnostic, Diagnostics, Electrode, ELISA, Enzyme, Fluorescence, immunity, Immunization, Lab-on-a-Chip, Liquid Handling, Membrane, Nasopharyngeal, Nuclease, Nucleic Acid, Palindromic Repeats, Pandemic, Polymerase, Polymerase Chain Reaction, Protein, Receptor, Respiratory, Reverse Transcriptase, Ribonucleic Acid, RNA, Sample Preparation, SARS, SARS-CoV-2, Severe Acute Respiratory, Severe Acute Respiratory Syndrome, Syndrome

Neha is a digital marketing professional based in Gurugram, India. She has a Master’s degree from the University of Rajasthan with a specialization in Biotechnology in 2008. She has experience in pre-clinical research as part of her research project in The Department of Toxicology at the prestigious Central Drug Research Institute (CDRI), Lucknow, India. She also holds a certification in C++ programming.

Please use one of the following formats to cite this article in your essay, paper or report:

Mathur, Neha. (2022, August 10). A novel 3D-printed lab-on-a-chip device concurrently detects SARS-CoV-2 nucleic acid and anti-SARS-CoV-2 antibodies in saliva. News-Medical. Retrieved on August 13, 2022 from https://www.news-medical.net/news/20220810/A-novel-3D-printed-lab-on-a-chip-device-concurrently-detects-SARS-CoV-2-nucleic-acid-and-anti-SARS-CoV-2-antibodies-in-saliva.aspx.

Mathur, Neha. "A novel 3D-printed lab-on-a-chip device concurrently detects SARS-CoV-2 nucleic acid and anti-SARS-CoV-2 antibodies in saliva". News-Medical. 13 August 2022. <https://www.news-medical.net/news/20220810/A-novel-3D-printed-lab-on-a-chip-device-concurrently-detects-SARS-CoV-2-nucleic-acid-and-anti-SARS-CoV-2-antibodies-in-saliva.aspx>.

Mathur, Neha. "A novel 3D-printed lab-on-a-chip device concurrently detects SARS-CoV-2 nucleic acid and anti-SARS-CoV-2 antibodies in saliva". News-Medical. https://www.news-medical.net/news/20220810/A-novel-3D-printed-lab-on-a-chip-device-concurrently-detects-SARS-CoV-2-nucleic-acid-and-anti-SARS-CoV-2-antibodies-in-saliva.aspx. (accessed August 13, 2022).

Mathur, Neha. 2022. A novel 3D-printed lab-on-a-chip device concurrently detects SARS-CoV-2 nucleic acid and anti-SARS-CoV-2 antibodies in saliva. News-Medical, viewed 13 August 2022, https://www.news-medical.net/news/20220810/A-novel-3D-printed-lab-on-a-chip-device-concurrently-detects-SARS-CoV-2-nucleic-acid-and-anti-SARS-CoV-2-antibodies-in-saliva.aspx.

Dr. Fei Liu and Dr. Luke P. Lee

In this interview, we speak to Dr. Fei Liu and Dr. Luke P. Lee about their new iTears platform and how it could help to diagnose disease from tears.

In this interview, we speak to Professor Kay Tye about her latest research into memories and how we can start to understand the emotions behind them.

We speak to Ali Safavi, CEO and Founder of Grenova about sustainable science, the impact life sciences research is having on our planet, and the solutions they offer for laboratories to help reduce their plastic waste.

News-Medical.Net provides this medical information service in accordance with these terms and conditions. Please note that medical information found on this website is designed to support, not to replace the relationship between patient and physician/doctor and the medical advice they may provide.

This site complies with the HONcode standard for trustworthy health information: verify here.

News-Medical.net - An AZoNetwork Site

Owned and operated by AZoNetwork, © 2000-2022